ERICCSON POCKETPHONE NOTES: This is a dual NAM unit. The ESN prefix is 143 decimal, 8F hex. General Electric: 1-800-528-7711 PROGRAMING: 1. Turn power on. 2. Within ten seconds press and hold the FCN key and enter 9 2 3 8 8 5. 3. The volume up key increments the step number. 4. Use any numeric key to toggle on/off options and NAM 1/2 select. 5. The END key completes programing and exits at any time. PROGRAMING DATA: STEP# #OF DIGITS/RANGE DISPLAY DESCRIPTION 01 11 (UNCHANGEABLE) SER NUMBER DECIMAL ESN 02 4 DIGITS LOCK CODE LOCK CODE 03 ON/OFF AUTO AUTO SYSTEM REGISTRATION 04 ON/OFF WHERE AUTO ROAM REGISTRATION 05 1/2 NAM x TOGGLE NAM 1 AND 2 06 10 DIGITS MIN MIN (AREA CODE & TEL#) 07 00000 - 32767 SID SYSTEM ID 08 ON/OFF LOC LOCAL USE MARK 09 ON/OFF MRK MIN MARK 10 333 OR 334 IPCH INITIAL PAGING CHANNEL 11 2 DIGITS ACCOLC ACCESS OVERLOAD CLASS 12 A/B PREF PREFERRED SYSTEM 13 2 DIGITS GIM GROUP ID (10 IN USA) At this stage the phone will return to step 05, you can either: Select the second NAM in which case steps 06 through 13 will repeat. Scroll through and check your entries, or press END to complete programing.